Operation – Lincoln Electric IM915 POWER FEED 10M SINGLE WIRE FEEDER User Manual

Page 27

Advertising
background image

B-5

OPERATION

B-5

1. STATUS LED

The status LED indicates system status. Normal
operation is a steady green light.

Note: During normal power-up, the LED may flash
red and/or green as the equipment performs self tests.

LED condition Definition

Steady green System okay. The power source and

wire feeder are communicating nor-
mally.

Blinking green Occurs during a reset and indicates

the power source is identifying each
component in the system. This is nor-
mal for the first 10 seconds after
power-up, or if the system configura-
tion is changed during operation.

Alternating

Non-recoverable system fault. If the

green and red power source or wire feeder status

LED is flashing any combination of
red and green, errors are present in
the system. Read the error code
before the machine is turned off.

Instructions for reading the error code
are detailed in the Service Manual.
Individual code digits are flashed in
red with a long pause between digits.
If more than one code is present, the
codes will be separated by a green
light.

To clear the error, turn the power
source OFF, and then back ON to
reset. See troubleshooting section.

Steady red

Non recoverable hardware fault.
Generally indicates a problem with
the cables connecting the wire feeder
to the power source.

Blinking red

Not applicable.

2.

DIGITAL METERS AND OUTPUT
ENCODER KNOBS

(See Figure B.2)

The primary weld procedure settings are controlled
and displayed using digital meters and output encoder
knobs located at the top of the POWER FEED

®

10M

Single Wire Feeder control panel.

POWER FEED

®

10M SINGLE WIRE FEEDER

FIGURE B.2

A. WIRE FEED SPEED/AMMETER DISPLAY

This meter displays either the wire feed speed or cur-
rent value (Amps) depending upon welding process
(Mode) being used and the status of the wire feeder
and power source. Written below the display is "WFS"
and "Amps". An LED light illuminates which value is
being displayed on the meter. The knob below the
meter adjusts the value displayed on the meters.

Prior to Welding

Description

CV Welding Processes Meter displays the preset

WFS value.

CC Welding Processes Meter displays the preset

Amps.

During Welding

An Weld Processes Meter displays displays the

actual average welding
Amps.

After Welding

An Weld Processes The meter holds the actual

current value for 5 sec-
onds. The display blinks to
indicate the POWER
FEED

®

10M Single Wire

Feeder is in the "Hold"
period. If the output is
adjusted while in the
"Hold" period, the POWER
FEED

®

10M Single Wire

Feeder will revert to the
"Prior to welding" display
described above.

Note: If the output knob for the WFS/AMPS is adjust-
ed while the POWER FEED

®

10M Single Wire Feeder

is in the “Hold” period, the POWER FEED

®

10M Single

Wire Feeder will immediately revert to the “Prior to
Welding” display.

The default wire feed speed units are inches/minute and
can be changed to meters/minute by entering the "Set-up
Menu" in this Operation Section. The wire feed speed is
calibrated to within ±2%. Refer to the power source man-

400

263

WFS AMPS

VOLTS TRIM

A

B

Advertising