Operation, B-30, B-30 weld mode searching – Lincoln Electric IM915 POWER FEED 10M SINGLE WIRE FEEDER User Manual

Page 52: Searching for a weld mode

Advertising
background image

B-30

OPERATION

B-30

WELD MODE SEARCHING

The Weld Mode Search feature allows the selection of
a welding mode based on certain criteria (wire size,
process type, etc.).

SEARCHING FOR A WELD MODE

To search for a mode, turn the control knob until
“Weld Mode Search” is displayed. This will appear in
between the highest and the lowest weld mode num-
bers.

Once “Weld Mode Search” is displayed, pressing the
right pushbutton labeled “Begin” will start the search
process.

During the search process, pressing the right pushbut-
ton typically acts as a “next” button and the left push-
button typically acts as a “back” button.

Rotate the control knob then press the right pushbut-
ton to select relevant welding details such as welding
process, wire type, wire size, etc.

When the final selection is made, the PF10M™ will
automatically change to the weld mode found by the
Weld Mode Search process.

Earlier products may not have this feature. To acti-
vate this feature, a software update may be needed
from www.powerwavesoftware.com

USER MEMORIES

Recall a memory with memory buttons

To recall a user memory, press one of the six user
memory buttons. The memory is recalled when the
button is released. Do not hold the button for more
than two seconds when recalling a user memory.

Recall a memory with the gun trigger

If desired, memories 2 through 6 can be recalled with
the gun trigger. For example, to recall memory 3,
quickly pull and release the gun trigger 3 times without
welding.

Note: the POWER FEED

®

10M Single Wire Feeder is

factory set with this feature disabled. Use the SETUP
menu and change P.4 to enable memory recall with
the gun trigger.

Save a memory with memory buttons

To save a memory, press and hold the desired memo-
ry button for two seconds. When the button is initially
pressed, the corresponding LED will illuminate. After
two seconds, the LED will turn off. Do not hold the
button for more than 5 seconds when saving a user
memory.

Note that memories may be locked in the Setup menu
to prevent accidental overwrite of the memories. If an
attempt is made to save a memory when memory sav-
ing is locked, the message "Memory save is
Disabled!" will appear briefly in the MSP4 display.

POWER FEED

®

10M SINGLE WIRE FEEDER

HOLD 2 SECONDS TO SAVE

PROCEDURE

MEMORY

A

GUN

B

1

4

2

5

3

6

M

M

RECALL

PRESS 1
SECOND

SAVE

PRESS 2

SECONDS

Advertising