Operation, Case front controls – Lincoln Electric IM956 POWER WAVE C300 User Manual

Page 25

Advertising
background image

B-4

OPERATION

B-4

CASE FRONT CONTROLS

(Code 11479)

All operator controls and adjustments are located on
the case front of the Power Wave. (See Figure B.1)

1. LEFT DISPLAY- Shows wire feed speed or amper-

age,

2. LEFT KNOB- Adjusts value in left display.

3. MAIN DISPLAY- Shows detailed welding and diag-

nostic information.

4. LEFT BUTTON- Changes the Main display to

show the Weld Mode or Arc Control.

5. MAIN KNOB- Changes the values on the Main dis-

play.

6. PROCEDURE BUTTON- Selects A or B proce-

dure, or gun control.

7. 2-STEP/4-STEP BUTTON- Toggles between 2-

step and 4-step trigger operation.

8. MEMORIES BUTTONS- For selection of common

procedures.

9. ON/OFF SWITCH- Controls power to the Power

Wave

®

C300.

10. RIGHT DISPLAY- Shows voltage or trim.

11. THERMAL LIGHT- Indicates when machine has

thermal fault.

12. RIGHT KNOB- Adjusts value in right display.

13. SET-UP- Lights when machine is in set-up mode,

14. IR PORT- Used to transfer information to palm

computers, etc.

15. RIGHT BUTTON- Used to toggle start options

and to end options.

POWER WAVE

®

C300

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

FIGURE B.1