B-11

OPERATION

B-11

GMAW (MIG) SYNERGIC WELDING

For each wire feed speed, a corresponding voltage is
preprogrammed into the machine. The nominal pre-
programmed voltage is the best average voltage for a
given wire feed speed, but may be adjusted to prefer-
ence. When the wire feed speed changes, the Power
Wave automatically adjusts the voltage level corre-
spondingly to maintain similar arc characteristics
throughout the WFS range.

UltimArc™Control, adjusts the apparent inductance of
the wave shape. The UltimArc™Control adjustment is
similar to the “pinch” function in that it is inversely pro-
portional to inductance. Therefore, increasing
UltimArc™Control greater than 0.0 results in a crisper
arc (more spatter) while decreasing the
UltimArc™Control to less than 0.0 provides a softer
arc (less spatter).

POWER WAVE

®

C300

START OPTIONS

END OPTIONS

SETUP

IR PORT

WELD MODE

UltimArc™ Control

Less
Deposition

More
Deposition

Shorter
Arc

Longer
Arc

+

+

AMPS

WFS

VOLTS

TRIM

220

26.4

EFFECT / RANGE
PINCH EFFECT
(-10.0 to +10.0)

DESCRIPTION

-

EFFECT

Preflow Time

Run-in WFS:

Start Procedure

DESCRIPTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding.

Run-In sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls
the WFS, Volts at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.

EFFECT

DESCRIPTION

Steel
Steel

Stainless

Stainless

Aluminum 4043

Aluminum 5356

ELECTRODE AND GAS

CO

2

Ar(Mix)
Ar(Mix)

Ar/He/CO

2

Ar
Ar

WIRE SIZE

0.030 0.035 0.045 0.052

---

10 20 24

94 11 21 25

61 31 41 ---
63 33 43 ---

--- 148 71 ---
--- 151 75 ---

WELD MODE

UltimArc™ Control

END OPTIONS

START OPTIONS

Pinch controls the arc characte-
-ristics when short-arc welding.

STEEL .035"

CV CO2

10

Spot Timer

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

Crater Procedure

Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.

Burnback:

The burnback time is the

amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.

Postflow Time

Adjusts the time that shielding
gas flows after the welding out-
put turns off.

Synergic CV programs feature an ideal voltage best
suited for most procedures. Use this voltage as a
starting point and adjust if needed for personal prefer-
ences.

When the voltage knob is rotated, the display will
show an upper or lower bar indicating if the voltage is
above or below the ideal voltage.

• Preset voltage above ideal

voltage. (upper bar displayed)

• Preset voltage at ideal

voltage. (no bar displayed)

• Preset voltage below ideal

voltage. (lower bar displayed)

BASIC OPERATION

CONTROL OPTIONS