Operation, B-18, Limits – Lincoln Electric IM956 POWER WAVE C300 User Manual

Page 39

Advertising
background image

B-18

OPERATION

B-18

To set limits, press the desired memory button 1-8
and hold for 5 seconds. Release the memory button
when the LED begins to blink rapidly and the MSP4
displays "Memory X Set Limits" as shown below.

POWER WAVE

®

C300

LIMITS

Limits allow the welder to adjust the welding proce-
dure only within a defined range.

Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memo-
ry 3 may not have any WFS limits.

Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.

The system machine limits are:

Parameter

Wire Feed Speed

Voltage

Trim

UltimArc™Control

Preflow

Start Time

Run-In WFS

Crater Time

Burnback Time

Postflow Time

Range

Weld mode and wire

feeder dependent.

Weld mode dependent

0.50 to 1.50

-10.0 to 10.0

0.0 to 2.5

0.0 to 10.0

Off, 50 to 150

0.0 to 10.0

0.00 to 0.25

0.0 to 10.0

Units

in/min

Volts

--

Weld mode dependent

Seconds

Seconds

in/min

Seconds

Seconds

Seconds

Limits may be set for:

• Wire Feed Speed/Amperage
• Voltage/Trim
• UltimArc™Control

Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to mem-
ory before entering the Limits Setup Menu.

A

GUN

B

1

5

2

6

3

7

4

8

M

M

Set Limits:

Press 5

seconds

START OPTIONS

END OPTIONS

SETUP

IR PORT

WELD MODE
UltimArc™ Control

Set Limits

Memory 2