B-15

OPERATION

B-15

POWER WAVE

®

C300

ALUMINUM GMAW-P (PULSED MIG)
AND GMAW-PP (PULSE ON PULSE)
WELDING

START OPTIONS

END OPTIONS

SETUP

IR PORT

WELD MODE
UltimArc™ Control

Less
Deposition

More
Deposition

Shorter
Arc

Longer
Arc

+

+

AMPS

WFS

VOLTS

TRIM

220

1.06

72

EFFECT / RANGE

PULSE

PULSE-ON-PULSE

FREQUENCY:

FREQ.MODULATION

(Low)-10.0 to
(High)+10.0

(Low)-10.0 to
(High)+10.0

DESCRIPTION

For Pulse -On-Pulse modes,
Arc controls changes the frequ-
ency modulation. The freque-
-ncy modulation controls the
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high values for fast travel
speeds and narrower welds.

For Pulse modes, Arc Control

changes the pulsing frequency.
When the frequency changes,
the Power Wave system auto-
matically adjusts the back-
ground current to maintain a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.

EFFECT

Postflow Time

RUN-IN WFS:

.

Start Procedure

DESCRIPTION

Adjusts the time that shielding

gas flows after the trigger is

pulled and prior to feeding wire.

Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.

EFFECT

FUNCTION

ELECTRODE AND GAS

ALUMINUM 4043
ALUMINUM 4043
ALUMINUM 5356
ALUMINUM 5356

Ar
Ar
Ar
Ar

WIRE SIZE

0.035 3/64 1/16

149 72 74

98 99 100

152 76 78
101 102 103

WELD MODES

START OPTIONS

END

OPTIONS

UltimArc™ Control

Aluminum 3/64"

Pulse 4043 Ar

Spot Timer

Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.

Crater Procedure

Crater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.

Burnback:

The burnback time is the

amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.

Postflow Time

Adjusts the time that shielding
gas flows after the welding out-
put turns off.

BASIC OPERATION

CONTROL OPTIONS