Do’s and don't’s for installing a unit, Pump performance curve drainmaker – Star Water Systems S1104 User Manual

Page 2

Advertising
background image

2

© Copyright 2004. All rights reserved.

1. Read all instructions before beginning in stal la tion.

2. Be certain that basin is on a fi rm level surface.

3. Do not use an automatic plumbing vent device.

4. Do not over-torque lid attachment screws.

5. Always use a check valve on the discharge line.

6. Test operation of pump per STEP 6.

Ten Helpful Hints For Easy Installation

Performance Characteristics for the Pump in the DrainMaker System

7. Always provide some means to disconnect basin from

plumb ing for maintenance purposes.

8. Run unit at least once a month to verify proper op-

er a tion.

9. The model number and date code can be found on

the lid warning label.

10. Plug pump into a properly grounded GFCI recep-

tacle.

009961AFW

TOTAL DYNAMIC HEAD

FLOW PER MINUTE

15

LITERS

0

GALLONS

20

40

5

10

0

2

5

25

100

80

60

20

30

PUMP PERFORMANCE CURVE

DRAINMAKER

FEET

METERS

4

10

15

6

20

009961BFW

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

DEWATERING ONLY

Shut-off Head:

15

4.6

Feet

Meters

5

10

1.5

3.0

MODEL

18 ft. (5.5m)

10

38

Gal.

Liters

29

22

110

83

1048

1. DO read all installation material included with the

pump.


2. DO inspect unit for any visible damage caused by ship-

ping. Contact dealer if unit appears to be damaged.


3. DO clean all debris from the basin and pump.

4. DO always disconnect pump from power source before

han dling. DO always connect to a separately protected
and prop er ly grounded ground fault protected circuit.
DO NOT ever cut, splice or damage power cord. DO
NOT carry or lift pump by its power cord. DO NOT use
an extension cord.

Do’s And Don't’s For Installing A Unit

5. DO NOT use a discharge pipe smaller than the pump

discharge size.


6. DO test pump immediately after installation to be sure

that the system is working properly.


7. DO review all applicable local and national codes and

verify that the installation conforms to each of them.

8. DO NOT install unit in the ground.