Van Air Systems D12-D36 User Manual

Page 3

Advertising
background image

PAGE 3

FIGURE 2 MAXIMUM CAPACITIES -SCFM (Nm

3

/hr)

MODEL

NO.

D-12

D-16

D-20

D-24

D-30

D-36

MAXIMUM
WORKING

PRESSURE

250 PSIG

250 PSIG

200 PSIG

200 PSIG

200 PSIG

175 PSIG

100 PSIG

6.9 Bar

100
170
155

263
250

425
375
637
625

1062

850

1444

125 PSIG

8.6 Bar

122

207
189

321
304
517
457
776
761

1293
1035
1759

150 PSIG

10.3 Bar

144
244
223

378
359

610
538
915
897

1525
1221
2074

40 PSIG

2.8 Bar

48

81
74

126
119
203
179
304
298
506
405
689

60 PSIG

4.1 Bar

65

111
101

172
163
277
244
415
407
692
554
941

80 PSIG

5.5 Bar

83

140
128

217
206
351
310
526
516
877
702

1192

20 PSIG

1.4 Bar

30
51
47
80
76

128
113
193
189

321
257

437

10 PSIG

0.7 Bar

22
37
33
57
54
91
81

137
135

229
183

311

5 PSIG

0.3 Bar

17

29
27
45
43
73
64

109
107
182
146

248

SECTION 2

INSTALLATION

FIGURE 3 RECOMMENDED INSTALLATION DRAWING

NOTE:

ITEMS CALLED OUT IN THIS DRAWING

ARE NOT SUPPLIED WITH THE DRYER.

REFERENCE FIGURES 1 & 4 FOR ITEMS

INCLUDED WITH DRYER.

175 PSIG

12.1 Bar

165
281
256

436
414

703
620

1054
1034
1757
1406
2390

200 PSIG

13.8 Bar

187
318
290

493
468

795
702

1193
1170
1988

--
--

250 PSIG

17.2 Bar

231
392
358
608

--

--
--

--
--
--
--
--

Advertising