F200 series filter iom, F200 series compressed air filters, Installation, operation & maintenance instruction – Van Air Systems FR-1200 User Manual

Page 19: Warnings, Product purpose & function, Operating conditions, Filtration grades

Advertising
background image

PAGE 1

WARNINGS

DO NOT REPLACE ANY ITEM ON FILTER WHILE IT IS PRESSURIZED.
DO NOT OPERATE A LEAKING FILTER. TAKE FILTER OUT OF SERVICE IMMEDIATELY.
DO NOT OPERATE ABOVE MAXIMUM WORKING PRESSURE (MWP) AT MAXIMUM OPERATING TEMPERATURE (°F).

(COALESCING)

IN/OUT

(PARTICULATE)

OUT/IN

April 2012

P/N 432-10016-D

FILTER DETAILS

FLOW DIRECTION THROUGH ELEMENT

OUTLET

INLET

OUTLET

INLET

FILTER

BOWL

FILTER

HEAD

ELEMENT

SUPPORT

ELEMENT

INLET/

OUTLET

PD-6 POP-UP

INDICATOR

(STANDARD)

THRU-BOLT

HOLES

BLANKING

PLATE

PRODUCT PURPOSE & FUNCTION:

Van Air's F200 series filters are designed to remove contaminants from compressed air systems. Available in 1/4" to 3"

connection sizes and flow capacities from 15 to 1250 SCFM (at 100 psig) in 15 housings and 9 filtration grades, the F200 series

can remove oil aerosols, oil vapors, water and particulates. Housings are made of cast aluminum and coated with an epoxy powder

coating for corrosion resistance. All units include push-on elements with durable polyester drain layer (except RD grade).

Accessories include differential pressure indicators, wall mounting kits, connector kits, and automatic drain valves.

OPERATING CONDITIONS

MAXIMUM WORKING PRESSURE

All Models

OPERATING TEMPERATURE

Minimum
Maximum

MAXIMUM RECOMMENDED INLET

TEMPERATURE

AA, A, RAA, RA, RB, and RC Series

B Series

C Series

RD Series

250 PSIG

35°F

225°F

225°F

175°F

125°F

80°F

ADM-2-2

(OPTIONAL)

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTION

F200 SERIES

COMPRESSED AIR FILTERS

FILTRATION GRADES

APPLICATION

ELEMENT

GRADE

PURPOSE

NOMINAL

PARTICULE

REMOVAL

ELEMENT

FLOW

DIRECTION

COLOR

CODE

OIL

REMOVAL

(LIQUIDS)

AA

Extra Coarse

Coalescing

25.00 μ

IN/OUT

WHITE

A

Coarse

Coalescing

5.00 μ

IN/OUT

GREEN

B

General Purpose

Coalescing

1.00 μ

IN/OUT

RED

C

High Efficiency

Coalescing

0.01 μ

IN/OUT

BLUE

PARTICULATE

REMOVAL

(SOLIDS)

RAA

Extra Coarse

Particulate

25.00 μ

OUT/IN

WHITE

RA

Coarse

Particulate

5.00 μ

OUT/IN

GREEN

RB

General Purpose

Particulate

1.00 μ

OUT/IN

RED

RC

High Efficiency

Particulate

0.01 μ

OUT/IN

BLUE

OIL VAPOR

REMOVAL

RD

Vapor Absorbing

0.01 μ

OUT/IN

WHITE