Van Air Systems FR-1200 User Manual

Page 3

Advertising
background image

PAGE 3

3.1 SPECIFICATIONS

WEIGHT .............3200 Lbs (without desiccant installed)
4508 Lbs (with desiccant installed)

DIMENSIONS ..................... See SECTIONS 3.2
IN/OUT CONNECTION....... 3" 150# RF FLANGE
VESSELS (desiccant towers)

Construction ................... Manufactured to the ASME CODE, Section VIII, Division 1.

Vessels stamped "U" designator.

Design Pressure ............. 175 PSIG

Design Temperature ....... -20

O

F TO 300

O

F

PIPING

Threaded fittings: ........... ASME B16.3

Threaded unions: .......... ASME B16.39

Flanges: ......................... ASME B16.5

Welded Fittings ............... ASME B16.9

Pipe: .............................. Carbon steel, Schedule 40

VALVES

Inlet ............................... Proprietary 3-way piloted shuttle valve

Outlet .............................. Two (2) Check valves, wafer type

Purge .............................. Normally closed, air operatied type

CONTROL AIR FILTER

Construction ................... Aluminum housing

SEPARATOR/PREFILTER, PREFILTER, AFTERFILTER

Construction ................... Aluminum housing

PRE-COOLER

Core. ...............................Aluminum

Fan..................................Polypropylene blades with Aluminum hub

Fan Guard ......................Steel

ELECTRICAL

Standard 115 Volt ........... 115-120V/1PH/50-60Hz

DESICCANT

Material ........................... Activated Alumina, 1/8" (2-5 MM) Bead type
Quantity Per Tower ....... 654 Lbs.

OPERATING CONDITIONS

Inlet Air Pressure ............................ MIN 60 PSIG ...........MAX 175 PSIG

Inlet Air Temperature ...................... MIN 40°F.................MAX 150

O

F

Ambient Air Temperature................ MIN 40

O

F ................MAX 120

O

F

SYSTEM RATED INLET CONDITIONS

Inlet Air Pressure ............................ 100 PSIG

Inlet Air Temperature ...................... 150

O

F (based on 85°F ambient and 15°F approach from the pre-cooler)

Relative Humidity (saturation) ........ 100% RH

DRYER FLOW CAPACITIES (SCFM) at various pressures (100

0

F)

60 PSIG 80 PSIG 100 PSIG 110 PSIG 125 PSIG 140 PSIG 150 PSIG

160 PSIG

175 PSIG

FR-1200

782 990 1200 1251 1324 1394 1438 1481 1543

SPECIFICATIONS

SECTION 3

Advertising