Van Air Systems HLSXA-55 User Manual

Page 6

Advertising
background image

PAGE 6

INSTALLATION

SECTION 4

Fill

ALL conduit seal fittings with Chico compound and Chico fiber per

the manufacturer's instructions.

The power connection to the control box is made through a conduit

connection in the top of the control box. Connect the proper conduit

and wiring as required by code. Connect the incoming power to the

three wires that protrude from the conduit connection. See ladder type

wiring diagram in

FIGURE 4D.

WARNING

IT IS CUSTOMER'S RESPONSIBILITY TO FILL ALL

CONDUIT SEAL FITTINGS (INCLUDING THE ONES

TO THE SOLENOID VALVES) WITH CHICO COM-

POUND AND CHICO FIBER TO ENSURE THE

INTEGRITY OF THE EXPLOSION PROOF RATING

The electrical controls for the HLSXA dryers are housed in a NEMA 4/7

rated metal enclosure that is explosion proof (Class 1, Div 1, Groups

C & D).

4.7 ELECTRICAL CONNECTIONS

WARNING

SERIOUS PERSONAL INJURY AND DAMAGE TO THE DRYER

WILL OCCUR IF THE DRYER IS CONNECTED TO A POWER

SOURCE OTHER THAN THE VOLTAGE LISTED ON THE DATA

TAG.

WHEN INSTALLING THE ELECTRICAL CONNECTIONS FOR

THIS DRYER, COMPLY WITH NATIONAL ELECTRICAL CODE

AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES

FIGURE 4B: DRYER PNEUMATIC SCHEMATIC

4.6 INSTALLING THE PURGE MUFFLER

The muffler was shipped separately. It should NOT be installed until

the dryer has been operated for several hours. From desiccant instal-

lation, some dust may be present in the desiccant towers. Operating

the dryer with the muffler installed immediately after the towers have

been filled with desiccant or at initial start up may cause the muffler to

clog.

IMPORTANT

The dryer must be operated for several hours without the muf-

fler after the towers have been filled with desiccant. This will

prevent the muffler from becoming clogged.

MODEL

HLSXA55

DRAIN

MANUAL/

AUTOMATIC

MODEL

F200-55-1/2-C

PD GAUGE

PD-6

DRAIN

MANUAL

MODEL

F200-55-1/2-RB

PD GAUGE

PD-6

PRE-FILTER

AFTER-FILTER

FIGURE 4C: RECOMMENDED PRE/AFTER FILTERS

WARNING

WHEN OPERATING THIS DRYER WITHOUT THE MUFFLERS

INSTALLED, USE HEARING PROTECTION.

Advertising