Section 6 - operation – Van Air Systems HLSXA-55 User Manual

Page 9

Advertising
background image

PAGE 9

6.2 MOISTURE INDICATOR

The moisture indicator is located in the tubing line from the control air

filter. The moisture indicator contains a sight glass window in a fitting

with an indicator strip inside. A sample of outlet air is directed through

the indicator.

The indicator strip will change colors from PINK (indicating wet gas)

to BLUE (indicating dry gas) as the relative humidity changes in the

sample of outlet air.

6.1 DRYER CONTROL

The dryer control is housed in a metal NEMA 4/7 explosion proof

enclosure (Class 1, Div 1, Groups C & D). See

FIGURE 6A for control

box.

The dryer control has the following features:

- Power ON Light

- Left Tower Drying Light

- Right Tower Drying Light

- Dryer Purging Light

OPERATION

SECTION 6

6.3 OPERATION

The dryer operates in a fixed 10 minute cycle. The dryer changes

towers every five minutes. The dryer goes through a normal tower

changeover sequence (repressurization, tower changeover, depressur-

ization). See

FIGURE 6B for dryer timing chart.

FIGURE 6A: CONTROL BOX

FIGURE 6B: DRYER TIMING CHART

Advertising