Speed / step setting – GW Instek LCR-8000G Series User Manual
Page 51

GRAPH MODE
101
101
101
101
Speed / Step Setting
Select measurement speed (capture timing)
Background
The speed is the same setting used in the basic
measurement (page56), except in the graph mode,
maximum speed setting is not available.
Panel operation
1. Press the Up/Down key and move
the cursor to Speed.
Speed:
Fast
2. If necessary, press the Left/Right
key to change the setting (time per
capture).
DC
AC≤
100Hz
AC≤
2kHz
AC>
2kHz
AC≥
1MHz
Slow
900ms 1.3s
600ms 600ms 620ms
Med
120ms 1.2s
470ms 450ms 470ms
Fast
60ms
650ms 180ms 150ms 150ms
LCR-8000G Series User Manual
102
102
102
102
Select step size
Background
The step size selects whether to plot every
captured data (step size 1) or to plot only the
selected data (step size 2, 4, 8 = every 2, 4, 8 data).
Step size 1: detailed graph, slow capturing
Step size 2, 4, 8: simplified graph, fast capturing
Panel operation
1. Press the Up/Down key and move
the cursor to Step size.
Step Size:
2 4 8
1
2. If necessary, press the Left/Right
key to change the setting.
Range
1 (plot all data), 2, 4, 8