GW Instek GPI-700A Series Programming Manual User Manual

Page 24

Advertising
background image

GPI/GPT SERIES PROGRAMMABLE EST

PROGRAMMER MANUAL

⎯ 45 ⎯

Return:

<NR2>

Examples:

:DCWStanding:TTIMe 5.0 set the DCW test time to 5 sec.

:DCWStanding:TTIMe? return 005.0 if the DCW test time setting is 5 sec.

:IRESistance:VOLTage

Function:

Set or query the IR test voltage.

Syntax:

:IRESistancce:VOLTage <NR1>

:IRESistancce:VOLTage?

<NR1> Please refer to the specification

Return:

<NR1>

Examples:

:IRESistancce:VOLTage 100 set the IR test voltage to 100V.

:IRESistancce:VOLTage? return 0100 if the IR test voltage setting is 100V.

:IRESistance:RMINimum

Function:

Set or query the IR test minimum resistance.

Syntax:

GPI/GPT SERIES PROGRAMMABLE EST

PROGRAMMER MANUAL

⎯ 46 ⎯

:IRESistance:RMINimum <NR1>

:IRESistance:RMINimum?

<NR1> Please refer to the specification

Return:

<NR1>

Examples:

:IResistance:RMINimum 100 set the IR test minimum resistance to 100MΩ.

:IResistance:RMINimum? return 0100 the IR test minimum resistance setting is

100MΩ.

:IRESistance:RMAXimum

Function:

Set or query the IR test maximum resistance.

Syntax:

:IRESistance:RMAXimum <NR1>

:IRESistance:RMAXimum?

<NR1> Please refer to the specification

Return:

<NR1>

Examples:

:IRESistance:RMAXimum 100 set the IR test maximum resistance to 100MΩ.

:IRESistance:RMAXimum? return 0100 the IR test maximum resistance setting

is 100MΩ.