GW Instek GPI-700A Series Programming Manual User Manual
Page 9

GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 15 ⎯
:UTILity:GBZero:STATe?
Query the GB zero check
:UTILity:GBZero:TEST
Start the GB zero check
:ACContinue:VOLTage <NR2>
Set the CAC test voltage
:ACContinue:VOLTage?
Query the CAC test voltage
:ACContinue:CMINimum <NR2>
Set the CAC test minimum current
:ACContinue:CMINimum?
Query the CAC test minimum current
:ACContinue:CMAXimum <NR2> Set the CAC test maximum current
:ACContinue:CMAXimum?
Query the CAC test maximum current
:ACContinue:RTIMe <NR2>
Set the CAC ramp time
:ACContinue:RTIMe?
Query the CAC ramp time
:DCContinue:VOLTage <NR2>
Set the CDC test voltage
:DCContinue:VOLTage?
Query the CDC test voltage
:DCContinue:CMINimum <NR2>
Set the CDC test minimum current
:DCContinue:CMINimum?
Query the CDC test minimum current
:DCContinue:CMAXimum <NR2> Set the CDC test maximum current
:DCContinue:CMAXimum?
Query the CDC test maximum current
:DCContinue:RTIMe <NR2>
Set the CDC ramp time
:DCContinue:RTIMe?
Query the CDC ramp time
:ACWStanding:VOLTage <NR2>
Set the ACW test voltage
:ACWStanding:VOLTage?
Query the ACW test voltage
:ACWStanding:CMINimum <NR2>
Set the ACW test minimum current
:ACWStanding:CMINimum?
Query the ACW test minimum current
:ACWStanding:CMAXimum <NR2> Set the ACW test maximum current
:ACWStanding:CMAXimum?
Query the ACW test maximum current
:ACWStanding:RTIMe <NR2>
Set the ACW ramp time
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
⎯ 16 ⎯
:ACWStanding:RTIMe?
Query the ACW ramp time
:ACWStanding:TTIMe <NR2>
Set the ACW test time
:ACWStanding:TTIMe?
Query the ACW test time
:DCWStanding:VOLTage <NR2>
Set the DCW test voltage
:DCWStanding:VOLTage?
Query the DCW test voltage
:DCWStanding:CMINimum <NR2>
Set the DCW test minimum current
:DCWStanding:CMINimum?
Query the DCW test minimum current
:DCWStanding:CMAXimum <NR2>
Set the DCW test maximum current
:DCWStanding:CMAXimum?
Query the DCW test maximum current
:DCWStanding:RTIMe <NR2>
Set the DCW ramp time
:DCWStanding:RTIMe?
Query the DCW ramp time
:DCWStanding:TTIMe <NR2>
Set the ACW test time
:DCWStanding:TTIMe?
Query the ACW test time
:IRESistance:VOLTage <NR2>
Set the IR test voltage
:IRESistance:VOLTage?
Query the IR test voltage
:IRESistance:RMINimum <NR2>
Set the IR test minimum resistance
:IRESistance:RMINimum?
Query the IR test resistance
:IRESistance:RMAXimum <NR2>
Set the IR test minimum resistance
:IRESistance:RMAXimum?
Query the IR test resistance
:IRESistance:RMAXimum <NR2>
Set the IR test maximum resistance
:IRESistance:RMAXimum?
Query the IR test resistance
:IRESistance:TTIMe <NR2>
Set the IR test time
:IRESistance:TTIMe?
Query the IR test time