HT instruments HT9022 User Manual
Page 32

HT9022
EN - 30
5.5.1.2. DC
power
The screen to the side shows an example of DC power
measurement.
Mod Par Sys
Fnz
D C
0 . 4 0
k W
19/01-17:00:00
5.5.1.2.1. Key F4 “Fnz” in DC Power measurement
While measuring DC Power, press key F4 (Fnz) to open the
drop-down menu shown on the screen to the side. At each
subsequent pressure of key F4, the cursor will scroll through the
available items, as follows:
• Max: it constantly displays the maximum value of the
measured parameter;
• Min: it constantly displays the minimum value of the
measured parameter;
• Rst: it deletes all stored Max and Min values;
Mod Par OK
Fnz
D C
0 . 4 0
k W
19/01-17:00:00
• Esc: it goes back to a normal measuring mode.
By pressing key F3 (OK), the selected item is confirmed.
To the side, an example of measurement with active Max
function. The display shows the active function.
Mod Par Sys
Fnz
M a x
D C
0 . 4 0
k W
19/01-17:00:00
5.5.1.3. DC voltage and current
The screen shows an example of DC Voltage and Current
measurement.
Mod Par Sys
Fnz
D C
8 0 . 0
V
2 0 . 0
A
19/01-17:00:00
Max
Min
Rst
Esc