23

Aquaculture Software

Pond Status Screen

The Pond Status screen offers a quick view of farm data from the last 24 hours.

Figure 12.1 Annotated Pond Status Quick View screen

1

Calibrate menu (Do not use)

If you need to remove an erroneous adjustment factor, send a value of 25.5.

2

Config menu—Set aerators, send test email, database, program settings
window

3

Status—Farm status window

4

Setup—Farm status window, allows you to configure Farm Status screen

5

Analysis—Access the Communication Test window and the Monitor Analysis
window

6

Language—Select English or Spanish

7

Feeding system menus

8

Pond—User-entered pond name

A small number in the lower-right corner of the box appears when there are 30
or fewer days left on the sensor cap.

9

Dissolved oxygen value—Running average of the last 3 readings. This
average is compared to the on/off limits. Zero is ignored unless there are 3
zeros in a row.

A red zero indicates that the buoy is not communicating with the host . The
buoy power supply, microprocessor, and radio should be checked.

A black zero indicates an oxygen sensor problem. The sensor is not sending
a signal to the microprocessor and needs to be serviced.