Vfm 3100 end (junction box end) procedures – KROHNE VFM 3100 EN User Manual
Page 18

18
1. Take VFM 3100 end of prepared remote signal
cable and align it as shown at right. Ready for
assembly.
2. As shown in the diagrams at right, making
sure that the drain wire is folded back against
the copper braid, push the cable assembly
into the remote connector. Push until the cable
bottoms out (cannot be pushed in any further).
Push rubber bushing into position and tighten
the knurled nut onto the remote connector to
create a good compression fit.
VFM 3100 End (Junction Box End) Procedures
VFM 3100
end
Push cable assembly
into connector
2 twisted pairs
Prepared remote
signal cable (VFM 3100 end)
refer to table 2
Drain wire folded back
Rubber bushing
Knurled nut
Knurled nut
Remote
signal cable
VFM 3100
end
Rubber bushing
Shrink tube or
electrical tape
2 twisted pairs
Junction box
connector
Compression fit of drain wire
and copper braid in contact
with connector for shielding
Table 7. Connection of Remote Signal Cable (Electronics End)