Technical data, 2 technical data – KROHNE OPTIBAR DP 7060 C EN User Manual

Page 63

Advertising
background image

TECHNICAL DATA

7

63

OPTIBAR DP 7060 C

www.krohne.com

04/2014 - 4003292001 - MA OPTIBAR DP 7060 C R01 en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

Piezoresistive differential pressure cell

Application range

Flow measurement (volume or mass flow) with corresponding differential pressure
transmitter in gases, vapours and liquids

Differential pressure measurement

Interface and density measurement

Level, volume and mass measurement of liquids

Measuring range

30 mbar...16 bar / 0.44...232 psi

Display and user interface

Display and user interface

Display and user interface

Display and user interface

Display on signal

converter

Dot-matrix display 45x27 mm / 1.77x1.06", illuminated

Display turnable in 90° steps

Digit size 13x7 mm / 0.51x0.27"

Ambient temperatures below -20°C / -4°F may affect the readability of the display

Display function

Measured value display or derived measured value such as filling height, density, interface
position, volume or mass flow and total counter

Warning and diagnostic information

All parameters are accessible via the operating menu

Operating and display

languages

German, English, French, Spanish, Portuguese, Italian, Dutch, Russian, Turkish, Polish and

Czech

Operation

Local operation via 4 push buttons on the display and adjustment module

Remote operation

PACTware

TM

, incl. Device Type Manager (DTM)

HART

®

Hand Held Communicator from Emerson Process

AMS

®

from Emerson Process

PDM

®

from Siemens

Integrated clock

Date format

Day / Month / Year

Time format

12 hours / 24 hours

Time zone

CET (Factory setting)

Rate deviation

Maximum 10.5 minutes / year

.book Page 63 Friday, May 2, 2014 10:25 AM