KROHNE BATCHFLUX 5015 K EN User Manual
Page 16
Installation and operating instructions
16 BATCHFLUX
 
 
3.2 Factory
settings
 
All operating data are factory-set according to 
your order specifications. 
 
To facilitate easy and rapid initial start-up, 
pulse output is - unless specified otherwise - 
set to process flow measurement in “2 flow 
directions“ so that the current flowrate is 
displayed and the volumetric flow counted 
independent of the direction of flow. 
 
 
 
 
 
 
Table of standard factory settings
The factory setting for the current and pulse 
outputs may occasionally cause measuring 
errors, particularly in the case of volume flow 
counting. For example, if pumps are switched 
off and a “backflow“ occurs that is not within 
the range of the low-flow cutoff (SMU), or if 
separate displays and counts are required for 
both flow directions. To avoid faulty 
measurements, therefore, it may be necessary 
to change the factory setting of some or all of 
the following functions: 
•
low-flow cutoff SMU, Fct. 1.3
•
pulse output P, Fct. 1.6
 
 
Function Setting
1.1
Full-scale range Q
100%
see instrument 
nameplate 
1.2
Time constant
3 s, for S (option)
1.3
Low-flow cutoff SMU
(do not change setting!)
ON: 4
%
OFF: 5
%
1.4 Display
1.5
Current output I (NO HARDWARE !)
(function must be set to “OFF“!)
 
OFF 
1.6
Pulse output P
 Function 
 Pulse 
value
Pulse
width
 
1 direction 
1000 pulses/s 
automaticly 
1.7
Status output (NO HARDWARE !)
(function must be set to “OFF“!)
 
OFF 
3.1
Language for display only
English (or other)
3.2 Flowmeter 
 Size 
 
Flow direction (see arrow on primary head)
see instrument 
nameplate 
+ direction 
3.4 Entry
code
no
3.5 User-definable
unit
Liter/h
3