4.5 Error messages in measuring mode
 
The following list gives all errors that are likely 
to occur during process flow measurement. 
Errors are shown in the display when “YES“ is 
set in Fct. 1.4 DISPLAY, subfunction 
“DISP.MSG.“. 
 
Error message
Discription of error
Error clearance
LINE INT.
Power failure 
Note: 
no counting during power failure 
Delete error message in RESET/QUIT 
menu. If necessary, reset totalizer. 
PULS.OUTP. P
Pulse output overranged. 
Note: 
totalizer deviation possible. 
Check instrument parameters and 
correct, if necessary. After cause has 
been eliminated, error message is 
deleted automatically. 
ADC
Analog/digital converter 
overranged. 
After cause has been eliminated, error 
message is deleted automatically. 
FATAL. ERROR
Fatal Error; all outputs set to 
“Min. values“. 
Please consult factory.
TOTALIZER
Totalizer has been reset.
Delete error message in RESET/QUIT 
menu. 