KROHNE IFC 020 Converter EN User Manual

Page 38

Advertising
background image

Installation and operating instructions IFC 020

5/7

5.8 Status output S

Fct. 1.07 STATUS S

Press key

→

.

Select function of status outputs, press

→

key

• ALL ERROR

(indicates all errors)

• FATAL.ERROR (indicates fatal errors only)

• OFF

(switched off, no function)

• ON

(indicates that flowmeter is operative)

• F/R INDIC.

(indicates direction for current and pulse outputs, F/R mode)

• TRIP. POINT

(setting range: 002 – 115 PERCENT of Q

100%

, full-scale range)

Transfer to number setting with

↵

key, 1st digit (cursor) flashes.

Change flashing digit (cursor) with

↑

and

↓

keys. Use

→

and

←

keys to shift cursor 1 place to right or left.

Press

↵

key to return to Fct. 1.07 STATUS S.

• Characteristic of status output

Switch open

Switch closed

OFF (switched off)

no function

ON (e.g. operation indicator)

power OFF

power ON

F/R INDIC.

Forward flow

Reverse flow

TRIP POINT (limit switch)

inactive

active

ALL ERROR (all errors)

errors

no error

FATAL.ERROR (fatal errors only)

errors

no error

Please refer to Sect. 3.2 “factory settings”

Refer to Sect. 2.4 for connection diagrams, and to Sect. 5.14 for characteristics.

Advertising