Battery replacement – KYORITSU 8113 User Manual

Page 12

Advertising
background image

― 10 ―

When the battery indicator LED blinks at a longer interval and
finally stops blinking , replace the battery as indicated below.
CAUTION : Do not replace the battery while measuring.
(1) Remove the test lead from the instrument and set the Power

switch to the off position.

(2) Loosen the screws of the battery compartment cover at the

back of housing. And then slide and remove the battery
compartment cover.

Note :

Do not loosen the
screws completely
to the end in order
to avoid losing them.

(3) Replace the battery with

new one.

(4) Push the battery

compartment cover and
fasten the screws firmly.

NOTE : T

O MEET VARIOUS APPLICATION NEEDS, THE 8113

IS DESIGNED TO BE HIGHLY SENSITIVE ON THE 2A
RANGE, RESULTING IN RESIDUAL OUTPUT NOISE
EQUIVALENT TO ±2mV APPROX. HOWEVER, THIS
DOES NOT INDICATE ANY FAULTY CONDITION. IN
CASE OF DC CURRENT, EARTH MAGNETISM
AFFECTS MEASUREMENTS. THEREFORE, THE
READING WILL SLIGHTLY VARY DEPENDING ON THE
ORIENTATION OF THE 8113 IN USE. TO MAKE
PRECISE MEASUREMENT, IT IS A RECOMMENDED
PROCEDURE TO ZERO ADJUST THE 8113 EVERY
TIME ITS ORIENTATION IS CHANGED.

5-2-3 Other applications

DC coupled and without distortion input waveform appears
on the output terminal of the instrument. This will permit
current waveform observation on the oscilloscope. When
connected to a recorder, it will also allow for a continuous
recording of input current. As a current sensor, the 8113 may
also permit a wide range of other applications.

6. Battery Replacement

Advertising