Specifications – KYORITSU 8113 User Manual

Page 4

Advertising
background image

― 2 ―

2. Specifications

Accuracy:

Output Voltage:

(Above accuracies are specified for + 18℃ to + 23℃ at < 80%

relative humidity)

Operating
Temperature
& Humidity :

−10℃−+50℃ at <85% relative humidity

Storage
Temperature
& Humidity :

−20℃−+ 60℃ at <75% relative humidity

Load
Resistance :

>1kΩ

Power Supply : 2×1.5V SUM-3 battery or equivalent

DC Current

AC Current

Measuring Ranges

0−

5A DC

0− 50A DC
0−200A DC

0−

5A AC

0− 50A AC
0−200A AC

Output

0−500.0mV DC(100mV/A)
0−500.0mV DC( 10mV/A)
0−200.0mV DC( 1mV/A)

0−500.0mV AC(100mV/A)
0−500.0mV AC( 10mV/A)
0−200.0mV AC( 1mV/A)

DC Current

AC Current

Measuring Ranges

0−

5A DC

0− 50A DC
0−150A DC

150−200A DC

0−

5A AC

0− 50A AC
0−150A AC

150−200A DC

Accuracy

±(1.5%rdg+5mA)
±(1.0%rdg+0.02A)
±(1.5%rdg+0.2A)
±3.0%rdg

±(2.0%rdg+5mA) DC-1kHz
±(1.5%rdg+0.04A) DC-1kHz
±(2.0%rdg+0.5A) DC-1kHz
±3.5%rdg DC-1kHz