NSi Industries P1101FM-M User Manual

P1101fm-m, Installation & wiring instructions, Time switch mechanism for pool panels

Advertising
background image

MODEL#:

P1101FM-M

120 VOLT, 24-HOUR MECHANICAL TIME SWITCH MECHANISM

w/ Fireman Switch (Heater Cutoff Switch)

CONTACT CONFIGURATION:

DPST (Double Pole Single Throw), (2) NO (Normally Open Contacts),

(1) NC (Normally Closed Contact)

TIME SWITCH RATING:

40A Resistive/Inductive per pole, 3HP @ 120V (NO Contacts);

15A General Purpose/Resistive

MODES OF OPERATION:

3 Operating modes available: Timer/AUTO, OFF/Standby, ON

FIREMAN SWITCH RATING:

15A, SPST @ 12OV

AUTOMATIC OPERATION:

Time Switch can be switched on or off in 15 minute increments for a multitude of on/

off operations per 24 hour period. See below for details on “modes of operation”.

IMPORTANT SAFETY INSTRUCTIONS

READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS

ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!

This control must be installed in accordance with National and Local Electrical Codes.

Disconnect power at main panel before installing or servicing this device.

USE COPPER CONDUCTORS ONLY

Do not exceed the ratings of this device, and current capacity of conductors

This control should not operate any equipment which would cause bodily injury or property damage should it be activate

unexpectedly.

1.

2.

3.

4.

5.

INSTALLATION & WIRING INSTRUCTIONS

To install Time Switch into control panel, insert lower back

edge of mechanism into Universal mounting plate located

in control panel. Push top front edge of mechanism down

into the mounting plate. You will here a click indicating

that the Time Switch is securely attached to universal

mounting plate.

To wire switch follow the wiring diagram provided.

Use solid or stranded COPPER wire only.

Strip the supply and load wires by removing 1/2 inch of

insulation.

Insert the wires under the proper terminal plates and

tighten the screws firmly.

1.

2.

3.

4.

5.

PROGRAMMING & OPERATING YOUR TIME SWITCH MECHANISM

SETTING THE TIME:

Rotate clock face in a clockwise direction until proper time is displayed. In order to properly set time

for AM or PM, verify that black arrow on clock face matches the correct 24-hour clock setting (example: 6=6AM, 18=6PM). If it

does not, rotate clockwise 1 complete turn for correct AM or PM setting.

SETTING “ON” and “OFF” TIMES:

Set the captive trippers for

desired on/off sequence required.

OFF-Push trippers IN (toward center of clock)

ON-Push trippers OUT (away from center of clock)

MODES OF OPERATION:

(Using 3-Position Rocker Switch)

Timer/AUTO: Automatic Time Switch operation according

to captive tripper’s on/off settings

OFF/Standby: Maintains proper clock time and Time Switch

program settings during periods of non-use.

ON: Used to override Timer/AUTO mode. User can turn the

Time Switch ON. Time Switch will remain ON until the user

switches back to TIMER/AUTO or OFF mode.

TORK, INC. • 888.500.4598 • www.TORK.com

®

TIME SWITCH MECHANISM FOR POOL PANELS

TIMER/AUTO
OFF/STANDBY
ON

MODES

A DIVISION OF

NSi INDUSTRIES, LLC

NOTE: There is no adjustment to fireman switch

120V TIMER

POWER

N

NEUTRAL

In

L1

LINE 1 In

L1

LINE 1 In

NO1

120V

LOAD OUT

NO2

120V

LOAD OUT

NC Aux

120V

LOAD OUT

120V Supply

NO 120V

Load #1

NO 120V

Load #2

NC 120V

Load

N

L

HTR

HTR

Fireman Switch:

120V, 15A, SPST

Will open Heater

Circuit Approx. 15-20

minutes prior to timer

pump shut-off

To Heater circuit

Factory

Installed

Jumper

E312471