SHIMPO FGS-100E User Manual

Page 8

Advertising
background image

7

4. Operation Panel Functions

1

2

3

4

1

7

11

8

6

10

5

No.

Names

Function

1

UP

Set Movement Speeds for Manual (MAU), JOGGING (JOg) Modes and during PUSH/
PULL Operation in 1 Cycle (SIg) and Continuous (CON) Modes.
inch/min Mode : Pressed once , the movement speed increases/decreases by 0.01
if pressed continuously , it changes at the rate of 0.1 .
mm/min Mode : Pressed once , the movement speed increases/decreases by 1 ,if
pressed continuously , it changes at the rate of 10 .

2

DOWN

3

MAX

Overrides to the maximum speed value possible of the Stand's motor when pressed.
Once released, the speed returns to the previous set value.

4

MODE

Scroll through the Modes (MAU)

5

LCD

Displays the condition of Movement Speed, Mode, Alarms. Etc.

6

PULL

Starts the Operation of PULL Direction

7

PUSH

Starts the Operation of PUSH Direction

8

STOP

Stops Test Operation

9

MAX_LED

Pressing MAX Key, when the Movement Speed is at Maximum, the Lamp lights.

10

PULL_LED

During PULL Operation it flashes

11

PUSH_LED

During PUSH Operation it flashes

LCD Normal Display

1) Sub Display Parts:
Presently selected Operation Mode is displayed at the top Sub-Display of LCD.
Limit Position, Over Load condition, or when the Emergency Stop is ON, the Operation Mode and all the Indicators
light-up alternately.

① Limit Position Reached in Operation Mode LMT Flashes
② Over Load Occurrence in Operation Mode OVR Flashes

③ When Emergency Stop is ON in Operation Mode EMg Flashes

2) Main Display Parts:

The set movement speed value is indicated in the main display.

Sub Display (Operation Mode)

Main Display (Movement Speed)

Advertising