Badger Meter ORION Classic (CE) User Manual

Page 6

Advertising
background image

2

The.loggers.monitor.the.water.mains.for.acoustic.noise.

during.the.nighttime.hours.when.the.system.is.in.its.

most.“quiet”.state..Our.system.is.designed.to.listen.at.

2:00.a.m...If.the.logger.hears.a.nearby.water.leak.in.

the.main,.it.listens.again.an.hour.later.to.be.sure.that.

what.it.heard.was.not.an.anomaly.in.the.system..If.it.

hears.the.leak.again.at.3:00.a.m.,.data.is.sent.to.the.

wired.AMR/AMI.endpoint,.which.in.turn.broadcasts.this.

data..
The.endpoint.broadcasts.its.unique.serial.number.as.

usual..In.its.reading.field,.it.sends.the.Permalog.data.

stating.if.a.leak.is.present.in.the.area.or.not..The.AMR/

AMI.transmissions.are.picked.up.during.the.normal.

meter.reading.process..Once.back.at.the.utility,.this.

data.is.put.into.a.report.generated.from.ReadCenter

®

.

software..The.ReadCenter.report.shows.all.the.leak.

loggers.that.are.reporting.a.leak.condition...
Normally.a.leak.is.picked.up.between.two.loggers..

From.the.report,.the.utility.can.use.leak.correlators.

and.ground.microphones.to.pinpoint.the.exact.location.

of.the.water.main.leak..This.process.increases.the.

efficiency.of.the.utility's.leak.detection.program.and.

also.pinpoints.the.location.of.leaks.requiring.repair.

ORION License Requirements

The.ORION.product.complies.with.Part.15.of.Federal.

Communications.Commission.Rules..Operation.of.this.

device.is.subject.to.the.following.conditions:.

This.device.may.not.cause.harmful.interference..

This.device.must.accept.any.interference.

received,.including.interference.that.may.cause.

undesired.operation..

An.FCC.license.is.not.required.by.the.utility.to.operate.

an.ORION.meter.reading.system.

GALAXY License Requirements

The.GALAXY.product.complies.with.Part.90.of.the.

Federal.Communications.Commission.rules..An.FCC.

license.is.required.to.operate.the.GALAXY.system.
Any.changes.made,.but.not.approved.by..

Badger.Meter,.can.void.the.user’s.authority.to.operate.

the.equipment.

Basic System Operation Overview

The.Permalog+.AMR/AMI.acoustic.leak.loggers.are.

wired.to.a.AMR/AMI.endpoint,.deployed.throughout.the.

utility.system.and.magnetically.attached.to.water.main.

valve.keys..

Advertising