Permalog+ AMR/AMI Acoustic Leak

Logger Placement Planning

Primary Variables of Sound Travel

When.determining.the.distance.between.each.

Permalog+.AMR/AMI.acoustic.leak.logger,.pay.

attention.to.the.variables.that.affect.how.sound.travels.

in.the.water.system.
1..

Pipe Material.-.Metallic.pipes.carry.sound.farther.

than.Transite.or.PVC.

2..

Pipe Diameter - Smaller.diameter.pipe.carries.

sound.farther.than.large.diameter.pipe.

3..

Pressure -.High.pressure.areas.carry.sound.better.

than.low.pressure.areas.

4..

Ground Water -.Sound.does.not.carry.well.in.high.

ground.water.conditions.

Spacing Guidelines

The.following.table.outlines.spacing.guidelines.and.the.

range.for.a.variety.of.pipes.

Type of Pipe

Range

Maximum

Spacing

Small Diameter

Steel and Iron

600.to.750.feet

1200.to..

1500.feet

Large Diameter

Steel and Iron

300.to.500.feet 600.to.1000.feet

Asbestos

Cement

300.to.500.feet 600.to.1000.feet

PVC

150.to.300.feet

300.to.600.feet

Poly

150.to.300.feet

150.to.600.feet

Using a Permalog+ AMR/AMI Leak Logger

When.working.with.the.Permalog+.system,.consider.

the.following..
•. . Keep.Permalog+.AMR/AMI.leak.loggers.away.

from.computer.hard.drives..The.strong.magnet.

attached.to.the.Permalog+.can.result.in.loss.of.

data.should.the.magnet.come.too.close.to.a.hard.

drive.

•. . To.activate.a.Permalog+.logger,.simply.swipe.the.

magnet.of.one.leak.logger.over.the.top.of.the.unit.

to.be.activated..The.LED.will.flash.several.times.

and.then.once.every.five.seconds..If.the.LED.is.

not.flashing,.swipe.again.

.
•. The.blinking.LED.indicators.on.the.top.of.the.

Permalog+.logger.indicate.if.the.unit.is.in.Leak.

mode.or.No.Leak.mode..In.Leak.mode,.the.red.

LED.will.blink..In.No.Leak.mode,.the.green.LED.

will.blink..Because.these.LEDs.are.not.bright,.you.

may.need.to.shield.the.LEDs.from.surrounding.

light.sources.to.determine.if.an.LED.is.flashing.

•. Prior.to.installation.we.suggest.that.you.contact.

your.local.police,.fire,.and.water.departments..

Provide.them.with.photos.and.brief.them.on.

the.operation.of.the.system..This.could.prevent.

emergency.services.from.identifying.the.

equipment.as.a.potentially.harmful.device.

•. Use.the.installation.tether.to.remove.and.install.the.

device.in.the.valve.box..Do.not.use.the.AMR/AMI.

radio.wire.to.install.or.remove.the.unit.