Unpacking the ORION Permalog+ AMR Acoustic

Leak Logger

To.unpack.the.unit,.follow.these.steps.
1. Unpack and lay out all ORION Permalog+

materials near the water valve box.

2.. Remove.the.valve.box.cover.
3.. Clean.off.the.valve.key.to.assure.a.good.magnetic.

connection.

Assembling the ORION Permalog+ AMR Acoustic

Leak Logger and Mounting Bracket

To.assemble.the.leak.logger.and.mounting.bracket,.

follow.these.steps.
1.. Place.the.ORION.Permalog+.and.cable.through.

the.opening.in.the.mounting.bracket.

2.. Attach.the.radio.endpoint.to.the.mounting.bracket.

by.placing.it.in.the.bracket.and.turning.it.one-

quarter.turn,.until.it.locks.

3.. Place.the.installation.tether.over.the.radio.

endpoint,.as.shown.below.

The.unit.is.now.ready.to.install.in.the.valve.box.
Mounting.

Bracket

Radio.

Endpoint

Installation.

Tether

Position, Install and Activate the ORION Permalog+

Acoustic Leak Logger

This.section.describes.the.most.efficient.method.of.

placing.the.ORION.Permalog+.AMR.leak.logger..

It.serves.as.a.guideline..You.may.need.to.make.

modifications.to.suit.your.specific.situation.
Before.you.begin:

Remove.all.magnet.keepers.and.plastic.washers.

from.the.ORION.Permalog+.AMR.acoustic.leak.

loggers.

Verify.that.all.ORION.Permalog+.magnets.are.

snug..

Note:.If.you.need.to.tighten.the.magnet.assembly,.do.

not.over-tighten.the.magnet..In.a.lift-and-shift.system,.

it.is.important.to.check.the.tightness.every.time.it.is.

retrieved..The.magnets.tend.to.loosen.when.removed.

from.the.valve.key.
1.. Prior.to.placing.an.ORION.Permalog+.in.a.valve.

box,.record.the.eight-digit.serial.number.labeled.on.

the.Permalog..This.will.identify.the.location.of.the.

unit..

2.. To.activate.the.Permalog+.logger,.swipe.the.

magnet.of.a.leak.logger.over.the.top.of.the.unit.to.

be.activated..The.LED.will.flash.several.times.and.

then.once.every.five.seconds..If.the.LED.does.not.

flash,.swipe.again.

Note: .The.Permalog+.leak.logger.should.be.placed.

carefully.on.a.clean.valve.key.
It.may.be.necessary.to.scrape.the.valve.key.to.assure.

good.contact.is.made..Failure.to.gain.good.contact.

between.the.Permalog+.and.valve.key.could.result.in.

poor.performance.and.erroneous.readings.
3.. Slowly.lower.the.leak.logger.into.the.valve.box.

using.the.attached.installation.tether.

.

Lowering.the.

leak.logger.using..

the.tether.

4. When the leak detector reaches the valve

key.it.

attaches.to.the.key.at.the.unit's.base.magnet.