INTRODUCTION

The Blancett Model 1200 in-line turbine flow meter was engineered for applications in high corrosive environments

Developed for use in petrochemical and other process industries with liquid chemical flows, the Model 1200 turbine provides

accuracy and durability in aggressive industrial environments The meter features a 303 stainless steel body and internal

wetted parts, with two type 440 stainless steel ball bearings

OPERATING PRINCIPLE

Fluid entering the meter passes through the inlet flow straightener, which reduces its turbulent flow pattern and improves

the fluid’s velocity profile Fluid then passes through the turbine, causing it to rotate at a speed proportional to the fluid

velocity As each turbine blade passes through the magnetic field, the blade generates an AC voltage pulse in the pickup coil

at the base of the magnetic pickup (see

Figure 1

) These pulses produce an output frequency proportional to the volumetric

flow through the meter The output frequency represents flow rate and/or totalization of fluid passing through the turbine

flow meter

Turbine Rotor

Magnetic Pickup

or

Other Frequency

Output Device

Output

Signal

Figure 1: Schematic illustration of electric signal generated by rotor movement