SPECIFICATIONS

Materials of Construction
Body

303 stainless steel

Rotor

CD4MCU stainless steel

Bearings

Two (2) type 440 stainless steel ball bearings

Rotor Support and Shaft

303 stainless steel

Operating Parameters
Temperature

Meter

–60…350° F (–51…177° C)

RF Pickup

–150…325° F (–101…162° C)

Pressure

4000 psi (276 bar) maximum

Accuracy

±0 5% of reading

Repeatability

±0 1%

Calibration

Water (NIST traceable calibration)

Corrosion

All Blancett Model 1200 turbine meters are constructed of stainless steel The operator must

ensure that the operating fluid is compatible with these materials Incompatible fluids can

cause deterioration of internal components and cause a reduction in meter accuracy

Pulsation and Vibration

Severe pulsation and mechanical vibration will affect accuracy and shorten the

life of the meter

Filtration

If small particles are present in the fluid, Blancett recommends installation of a strainer

upstream of the meter (see

Table 1

for filtration recommendations)

RF Preamplifier
Input Signal

1 millihenry carrier pickup

Output Signal

10V peak to peak square wave

Temperature
Module

–20…160° F (–7…71° C)

Pick-up

–150…325° F (–101…162° C)

Power

7…30V DC

Distance Specification

50 ft maximum between pickup and RF preamplifier

1000 ft maximum between preamplifier and receiving unit

Electrical Connection

Terminal strip

Housing

Epoxy encapsulated module