Introduction, Operating principle, Specifications – Badger Meter 900 User Manual

Page 5: Introduction 5, Operating principle 5, Specifications 5

Advertising
background image

INTRODUCTION

The Blancett Model 900 positive displacement flow meter provides the petrochemical industry with an economically priced,

high pressure flow meter for low viscosity liquids The Model 900 was designed for water flood and oil field service, but can

be used wherever totalization is necessary The meter is designed with wear resistant parts to provide trouble-free operation

and long service life The meter housing is made from stainless steel Internal parts are constructed of stainless alloys and high

strength engineering polymers to provide good chemical and abrasion resistance Maintenance kits are available to allow

quick and easy in-line repair

OPERATING PRINCIPLE

The liquid enters the measuring chamber through a precision inlet insert and separates into two equal streams The streams

cause the impeller assembly to rotate at a rate directly proportional to the flow rate Both liquid streams are then combined at

the meter outlet

FLUID

FLOW

(IN)

(OUT)

Figure 1: Operating principle

SPECIFICATIONS

Flow Range

Low Range

68…172 bpd (2…5 gpm)

Mid Range

172…1543 bpd (5…45 gpm)

High Range

1543…3086 bpd (45…90 gpm)

Materials of Construction

Body

Stainless steel body

Internal Components

Stainless steel alloys and high tech polymers for high chemical/abrasion resistance

Connections

1 in NPT female and 2 in NPT male

Operating Limitations

Temperature:

30…200° F (–1…93° C)

Not to be used on temperatures below the freezing point of liquid being measured

Pressure:

5,000 psi maximum

Accuracy:

±2 0% of reading

Repeatability:

±0 1%

Corrosion:

Contact Blancett at (800)-235-1638 to determine if operating liquid is compatible with

materials of construction Incompatible fluids could deteriorate internal parts and cause the

meter to read inaccurately

Pulsation and Vibration: Severe pulsation and mechanical vibration affect accuracy and shorten the meters life

Filtration:

A strainer capable of removing particles 0 020 in (0 50 mm) should be installed upstream

of the meter