TROUBLESHOOTING GUIDE

Trouble

Possible Cause

Remedy

No indication on register

• Debris in measuring chamber

• Broken magnet in magnetic drive
• Broken teeth on drive or driven gear
• Broken gears or shaft in register assembly

• Disassemble meter, clean out debris and

inspect for worn parts

• Replace magnetic drive
• Replace gear(s)
• Replace register

Low flow indication

• Flow rate is too low
• Bypass valves are leaking

• Increase flow above minimum rated gpm
• Close valves completely, repair or replace

High flow indication

• Gas in liquid
• Debris covering a portion of the

meter inlet

• Liquid is leaking around the inlet insert

• Install gas eliminator ahead of meter
• Remove meter from line and clean out debris

• Remove meter from line, remove insert and

reset with RTV

REPAIR KIT INFORMATION

Part Number

Repair Kit Description

B250-921

Complete Repair Kit; 42 Gallon Barrel; Low Range

B250-925

Complete Repair Kit; 42 Gallon Barrel; Mid Range

B250-923

Complete Repair Kit; 42 Gallon Barrel; High Range

B250-927

Complete Repair Kit; US Gallons

B250-931

Complete Repair Kit; Cubic Meters

B250-922

Repair Kit less Register; 42 Gallon Barrel; Low Range

B250-926

Repair Kit less Register; 42 Gallon Barrels; Mid Range

B250-924

Repair Kit less Register; 42 Gallon Barrels; High Range

B250-932

Repair Kit less Register; US Gallons

B250-928

Repair Kit less Register; Cubic Meters