Specifications – Badger Meter PVC Tee - 1 1/2 to 4"" User Manual
Page 10
Series 228PV Plastic Tee Type Impeller Flow Sensor
SPECIFICATIONS
Wetted Materials (except tees)
See "Ordering Matrix" in Technical Brief for material specifics.
Tee for 228PV
Schedule 80 PVC per ASTM D-2462 and D-2467, Virgin, unplasticized PVC resin, Type 1 cell
classification 12454-B. Fittings and solvent carry approval for potable water by NSF and IAMPO.
Pressure/Temperature
Ratings
(DO NOT EXCEED)
Depends on hardware configurations.
Temperature (°C)
0
20
40
60
80
100
0
25
60
Pr
es
su
re
(psi
)
Rated Temperature
(DO NOT EXCEED)
Operating: 35…110° F
Storage 14…110° F
Recommended Design
Flow Range
0.5…30 ft/sec
Accuracy
± 1.0% of full scale over recommended design flow range
Repeatability
± 0.3% of full scale over recommended design flow range
Linearity
± 0.2% of full scale over recommended design flow range
Transducer Excitation
• 8…35V DC max. input, source limited to 100 mA
• Quiescent current 600 uA @ 8…35V DC max.
• Quiescent voltage (Vhigh=Supply Voltage–(600 uA*Supply impedance))
• ON State (Vlow) Max. 1.2V DC @ 40 mA current limit (15 Ω + 0.7V DC)
Output Frequency
3.2…200 Hz
Output Pulse Width
5 msec ±25%
Environmental
• IP 68 / NEMA 4X
• Suitable for pollution degree 4 environments
• Suitable for outdoor use above grade, IR version below grade
• Suitable for use in 100% humidity
Electrical Cable for Standard
Sensor Electronics
20 feet of 2-conductor AWG 20 with AWG 22 drain wire shielded UL type PTLC wire provided for
connection to display or endpoint unit. Rated to 105° C. May be extended to a maximum of 2000
feet with similar cable and insulation appropriate for application.
Electrical Cable for IR Sensor
Electronics
48 inches of UL Style 116666 copper solid AWG 18 wire w/direct burial insulation. Rated to 105° C.
Page 10