MAINTENANCE

Maintenance Equipment

With the exception of a special change gear mesh gage and a calibration test tank, the tools required are the usual

compliment of standard hand tools used by plumbers and mechanics

Truarc Right-Angle Pliers

Truarc P/N 1549 (Badger Meter P/N 57321-001)

Change Gear Mesh Gage

Badger Meter P/N 21747-000

Preventive Maintenance

Periodic Inspection

1 Visually inspect the turbo meter and meter-mounted accessory Repair or replace components as required based on the

visual inspection

2 Verify that the meter operates at the proper flow rate and pressure A loss in pressure, coupled with the resulting decrease

in flow rate, may indicate the screen in the upstream pipeline is clogged with material and requires cleaning

Cleaning

1 Clean all dust, dirt, grease, moisture or other foreign material from the exterior of the meter and meter-

mounted accessory

2 If the piping arrangement of the facility includes a flushing system, shutoff the liquid flow to the meter Flush the interior

of the meter with an appropriate cleaning fluid to remove any buildup of deposits or corrosion on the internal portion of

the meter

Calibration Check and Adjustment

Accuracy of Badger turbo meters is tested at the factory with water However, due to possible use of liquids that could vary

in viscosity, it may be necessary to recalibrate a meter under operating conditions The following instructions are to assist in

performing a calibration adjustment

Accuracy Test

1 Place a test tank of known volume at output of meter
2 Operate the meter until the test tank is filled to a calibrated level Run at the actual flow rate used in the operation
3 Record the quantity indicated on the meter accessory
4 Perform the following calculations to determine percent of accuracy of the meter-accessory combination:

Qty Indicated on Accessory

X 100 = Meter Accuracy

Actual Quantity in Test Tank

Example 1:

95 Gallons

x 100 = 95% Accuracy

100 Gallons

In this example, the accessory is slow and must be speeded up by a change gear or electronic scaling correction
Example 2:

104 Gallons

X 100 = 104% Accuracy

100 Gallons

In this example, the accessory is fast and must be slowed down