Pulse output programming – Badger Meter Registers User Manual
Page 11
Pulse Output Programming
The Pulse Output can be programmed for any engineering unit of measure . A Pulse Output Scale Factor must be calculated and
programmed (Program Mode 6) using the same formula and procedure as described under the Totalizer Scale Factor (Program
Mode 1) .
The transmitter pulses per unit in Table 3 apply to the following transmitters:
• FT-1
• FT-1E
• FT-2
• PFT-2
• PFT-2E
• PFT-3
• FT-420
• PFT-420
Size
Meter Model
US Gallons
Liters
Ft
3
1/2"
OP
222 .960
58 .899
1687 .857
1/2"
OP (FT1 only)
111 .500
29 .455
834 .078
1"
OP
76 .640
20 .246
573 .307
2"
OP
20 .600
5 .442
154 .099
2"
Industrial Turbo
17 .360
4 .586
129 .862
3"
Industrial Turbo
12 .400
3 .276
92 .758
4"
Industrial Turbo
2 .560
0 .676
19 .150
6"
Industrial Turbo
1 .080
0 .285
8 .079
5/8"
LP RCDL
229 .554
60 .641
1717 .186
5/8"
25 RCDL
198 .340
52 .396
1484 .689
3/4"
35 RCDL
126 .671
33 .463
947 .566
1"
40 RCDL
89 .781
23 .717
671 .610
1"
55 RCDL
58 .064
15 .339
434 .351
1"
70 RCDL
46 .752
12 .350
349 .726
1-1/2"
120 RCDL
23 .867
6 .305
178 .539
2"
170 RCDL
14 .565
3 .848
108 .955
1-1/2"
160 Turbo Series
1 .537
0 .406
11 .495
2"
200 Turbo Series
1 .537
0 .406
11 .495
3"
450 Turbo Series
1 .598
0 .422
11 .955
4"
1000 Turbo Series
1 .665
0 .440
12 .455
6"
2000 Turbo Series
0 .150
0 .040
1 .122
8"
3500 Turbo Series
0 .151
0 .040
1 .133
10"
5500 Turbo Series
0 .198
0 .052
1 .481
12"
6200 Turbo Series
0 .129
0 .034
0 .963
16"
6600 Turbo Series
0 .016
0 .004
0 .116
20"
10000 Turbo Series
0 .009
0 .002
0 .067
1/2"
Industrial OG
378 .5 *
100 *
2831 *
3/4"
Industrial OG
249 .8 *
66 *
1868 *
1"
Industrial OG
249 .8 *
66 *
1868 *
1" HF
Industrial OG
162 .8 *
43 *
1217 *
1-1/2"
Industrial OG
64 .4 *
17 *
481 *
2"
Industrial OG
34 .1 *
9 *
255 *
3"
Industrial OG
11 .4 *
3 *
85 *
* If using a PFT-3E transmitter, multiply number by 2 .
Table 3: Transmitter pulses per unit
User Manual
Page 11
March 2014
REG-UM-00836-EN-11