OPERATION

Display Types

R

34675890

R

R 2345

Figure 4: Total display

Figure 5: Rate display

Total Display
Total Display indicates the present count value, which is equal to the number of pulses received (since the last reset)

multiplied by the Totalizer Scaler Value in program mode 1 .
Rate Display
Rate Display indicates the rate value, which is equal to the input frequency multiplied by the Rate Prescale Value in program

mode 4 . (If no pulses are received for 2 seconds, the rate value goes to zero .)

Control Keys

Down arrow key

Normal operating mode

When you press the Down Arrow

key during normal operation, the ER-9 toggles the display of the Flow Total and the

Flow Rate . The letter R on the left of the screen indicates that the Flow Rate is being displayed .
Programming mode

The Down Arrow

key toggles the unit between the Total Display and the Rate Display . When the program input is active,

press the Down Arrow

key to scroll through the menu items . After a menu item has been chosen for editing, press the

Down Arrow

key again to set the value for the currently selected (flashing) digit .

Reset key
While the Total Value displays, press the Reset

R

key to reset the value to zero . The front panel Reset function works only

when Program Mode 7 is preset to enable .
When the program input is active (see

“Wiring Instructions” on page 7

), press the Reset

R

key to select a menu item

for editing .