background image

INSTALLATION

Panel Installation

Place the unit in the panel through a 33 mm x 68 mm cutout . Slide the included gasket over the rear of the unit, then slide

the panel mount bracket into place so that the 4 tabs catch in the grooves on the top and the bottom of the unit (the bracket

should be oriented so that the tabs are on the side nearest the panel) . Use the provided panel mount screws to tighten the

bracket until there is a secure seal against the gasket . Do not over tighten .

72 mm

8

7

6

5

1

2

3

4

68 mm

33 mm

36 mm

Mounting

Bracket

Gasket

Tabs

Figure 1: Panel installation

Battery Installation/Replacement

The ER-9 is shipped with two batteries . Remove the battery cover by pushing inward and down . Install the batteries in the two

slots . Once the batteries are in place, the unit goes into a self-test mode, and all the segments on the LCD display illuminate .

To exit the self-test mode, press the Reset/Select

R

key . The unit then displays the model number 9 for the ER-9 . Press the

Reset/Select

R

key again to ready the unit for operation .

Battery

Battery

+

+

-

-

Figure 2: Battery installation