Dwyer DPL110 User Manual

Dwyer instruments, inc, Physical data

Advertising
background image

BULLETIN E-81-DPL

Model DPL Dual Point Level Switch

Specifications– Installation and Operating Instructions

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, ,U.S.A. Fax: 219/872-9057

e-mail: [email protected]

Lit-By Fax: 888/891-4963

DESCRIPTION
Maintain liquid level high and low limits with the Model
DPL Dual Point Level Switch. Units can be used for sin-
gle or dual point level control in semi-solid liquids, in-
dustrial slurries or heavy-bodied liquids like wastewater.
Standar 24 inch electrodes can be cut by the end-user to
a shorter length or lengthened by adding up to two 24
inch extensions (sold separately) to reach the maximum
recommended length of 72 inches. Model DPL contains
no moving parts to get stuck or wear out. Controller fea-
tures adjustable sensitivity and DIN rail-mountable sock-
et mount.

INSTALLATION

Conductivity Probes
1. Probes can be cut to length. Remove probes from

sensor head by carefully unthreading them from
inserts. Do not overtighten when re-installing.

2. Cut two (2) probes to the same length, these will be

the common and lower level probes. See figure 1.

3. Cut one (1) probe to the desired length for the upper

level of the tank. See figure 1.

4. Spacer should be located approximately 1 inch

(25.4 mm) from bottom of shortest probe.

5. If build up occurs on probes a short circuit could

occur. If this happens apply shrink tubing to the
probes leaving the last

1

/

2

inch (12.7 mm) bare.

Wiring (from sensor head to controller)
1. Install cable into sensor head through the compres-

sion fitting supplied.

2. Attach the black lead between the common probe

terminal and terminal five (5) on the socket mount.
See figure 2.

27.050

[687.07]

24.000

[609.60]

1" NPT

0.125

[3.18]

3.110

[78.99]

2.385

[60.58]

Ø2.260
[57.04]

1.395

[35.43]

3.731

[94.78]

2.810

[71.37]

2.250

[57.15]

1.750

[44.45]

PHYSICAL DATA

Electrodes:

1

/

8

؆ dia, 24Љ length, standard.

Wetted Parts: 316 Stainless Steel, polypropylene. All
food grade materials.
Mounting, Sensor Head: 1

Љ NPT.

Maximum Pressure: 30 psig (2.06 bar).
Maximum Operating Temperature: 212˚F (100˚C) .
Connecting Cable, Probe to Controller: 10 ft (3.0 m).
Sensing Voltage: 12 VAC.
Probe Sensitivity: Adjustable to 100,000 Ohms
Power Supply: 120 VAC 50/60 Hz.
Output: SPDT, 5 Amps @ 240 VAC.
Probe Enclosure: IP68 (NEMA 6).
Maximum Probe Length: 72

؆ (1.8 m) with optional

extensions.
Mounting, Controller: Standard octal socket or 35mm
DIN rail.
Electrical Connections: Screw terminals located on
socket mount.
Weight, Probe Assembly: 1.5 lbs (0.68 kg).
Weight, Controller: 1.0 lb (0.45 kg).

Upper
Level

Lower
Level

Common
Level

Spacer

Figure 1