Dwyer BGM User Manual

Dwyer instruments, inc, Series bgm bar graph meter, Installation and operating instructions

Advertising
background image

The Series BGM Digital Bar Graph Meter is extremely durable and can
replace a wide range of analog meters. The 4-digit display will
significantly reduce the potential for human error in reading by eliminating
errors commonly produced by the viewing angle when reading analog
meters. This series has a key pad that allows for easy access of features
without complex menu structures. With the combined ability to create a
wide range of custom faceplate and the optional NEMA 4X bezel, the
Series BGM can be used in a variety of applications. The LED bar graph
adds a visual indicator of the measured value so that it can be visually
analyzed, preventing accidents or system failures from happening.

POWER SUPPLY SPECIFICATIONS

120 VAC UNITS
Input Voltage Range: 85 to 140 VAC
Input Frequency Range: 47 to 63 Hz
Power Dissipation: < 3 VA

P4 WIRING

P4 - 1 : Neutral Line
P4 - 2 : 120 VAC Hot Line
P4 - 3 : Chassies Ground - Read Cautions

5 TO 12 VDC UNITS
Input Voltage Range: 5 TO 12 VDC
Permissable Ripple: 200 mV Max
Input Current: < 200 mA

P4 WIRING

P4 - 1 : GROUND
P4 - 2 : + DC
P4 - 3 : Chassies Ground - Read Cautions

10 TO 30 VDC UNITS
Input Voltage Range: 10 TO 30 VDC
Permissable Ripple: 500 mV Max
Input Current: < 150 mA

P4 WIRING

P4 - 1 : GROUND
P4 - 2 : + DC
P4 - 3 : Chassies Ground - Read Cautions

Series BGM Bar Graph Meter

Installation and Operating Instructions

Bulletin PC-BGM

SPECIFICATIONS
Inputs:
0 to ±10 VDC or 4 to 20 mA.
Accuracy: ±0.05% FS.
Power Requirements: 120 VAC 50/60 Hz, 5 to 12 VDC, or 10 to 30 VDC model
dependent.
Power Consumption:

120 VAC: 2.4 W @ 20 mA max;
5 to 12 VDC: 1.2 W @ 100 mA max;
10 to 30 VDC: 1.5 W @ 50 mA max.

Display:

LED Display: 4 red colored digits, 0.3˝ height;
LED Graph: 31 element bar, 0.2˝ W x 3.1˝ L (5.08 mm W x 78.74 mm L).

Decimal Point: 3 positions, user selectable.
Temperature Limits:

Operating: -13 to 176°F (-25 to 80°C);
Storage: -67 to 176°F (-55 to 80°C).

Enclosure Rating: NEMA 1 or NEMA 4X

, model dependent IP65 front.

Electrical Connections: Removable screw terminal blocks.
Outputs: 2 SPST relay outputs (optional).
Switch Rating: 1 A @ 200 V.
Enclosure Material:

Bezel: Black epoxy enameled steel;
Window: Acrylic;
Case and Mounting Bracket: 304 SS.

Time Delay: 0.5 sec.
Weight: 40 oz (1.13 kg).

XXXX

TARE

MENU

VALLEY

>

PEAK

SETPT/
RESET

XX.X

XX.X

XX.X

XX.X

XX.X

XX.X

L1
L2

1-13/32

[35.56]

5-45/64

[144.78]

VERTICAL

21/64

[8.33]

21/32

[16.51]

19/32

[14.99]

51/64

[20.07]

55/64

[21.84]

17/64

[6.92]

21/64

[8.33]

3-51/64

[96.39]

25/32

[19.81]

55/64

[21.72]

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

Wiring Guide

Rear View

Vertical

Horizontal

Advertising