Dwyer LCT316 User Manual

Dwyer instruments, inc, Series lct316 low cost digital timer

Advertising
background image

Series LCT316 Low Cost Digital Timer

Specifications - Installation and Operating Instructions

Bulletin PC-LCT316

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

The Series LCT316 Low Cost Digital Timer provides accurate
countdown timing for a variety of applications. The timer can be
triggered remotely using the digital input terminals or locally via
the set button. Time intervals can be set up to 999 minutes or
seconds. The Series LCT316 has an internal buzzer to alert
when the time interval has expired.

INSTALLATION

Unit must be mounted away from vibration, impacts, water and
corrosive gases.

• Cut hole in panel 2.80 x 1.14 inches (71 x 29 mm).
• Apply silicone (or rubber gasket) around the perimeter of the

hole to prevent leakage.

• Insert unit into hole of panel.
• Slide removable fitting clips onto unit from the back until

secure to panel.

• Wiring diagram as seen in figure A is displayed on the top of

the unit.

SPECIFICATIONS
Operating Temperature Range:
32 to 158°F (0 to 70°C).
Control Output Ratings: Relay, SPST NO, 16A at 250 VAC
resistive.
Weight: 5.6 oz (158.8 g).
Status Light: LED shows time and operation.
Inputs: Digital input for start and reset.
Supply Voltage: 115 VAC, 230 VAC, 12 VAC/DC, 24
VAC/DC depending on model.
Power Consumption: 4VA.
Agency Approvals: CE, UR.

NOTICE

Figure A

1-1/8

[28.57]

2-7/16

[61.91]

3

[76.20]

1-11/32

[33.99]

REMOTE

COUNTDOWN

INPUT

WIRING DIAGRAM

POWER

SUPPLY

OUT

OUTPUT

1

2

3

4

5

6

7

PC-LCT316:TEMPLATE 8/3/09 11:12 AM Page 1

Advertising