Dwyer DLP User Manual

Dwyer instruments, inc, Series dlp pressure data logger

Advertising
background image

Bulletin DA-DLP

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

Specifications - Installation and Operating Instructions

Series DLP Pressure Data Logger

The Series DLP is a data logger that can record pressure and
temperature. The 1/4˝ NPT fitting comes standard and allows the logger
to be adapted to almost any pressure fitting. The internal temperature
sensor provides accurate temperature measurements without the need
of a separate temperature recorder, and many of the models provide a
choice between measuring pressure in PSIA or PSIG. The DLP can
easily be started and stopped from a PC or delayed to start up to six
months in advance. The battery-powered data logger can store over
16,000 measurements per channel, and the easy to use DL700 software
makes retrieving data simple.

SPECIFICATIONS
Range:
Temperature: -40 to 176°F (-40 to 80°C); Pressure: 0 to 30
psia(g), 0 to 100 psia(g), 0 to 300 psia(g), 0 to 500 psia(g), 0 to 1000
psia, and 0 to 5000 psia depending on the model.
Memory Size: 16,383 readings per channel.
Accuracy: Temperature: ±1.0°F (±0.5°C); Pressure: 2% FSR, 0.25% at
77°F (25°C) typical.
Resolution: Temperature: ±0.2°F (±0.1°C); Pressure: 0.002 psia(g),
0.005 psia(g), 0.05 psia(g), 0.05 psia, and 0.2 psia depending on the
model.
Sampling Rate: Selectable from 2 sec to 12 hrs.
Computer Requirements: Windows Vista, Windows 7 and Windows

®

XP (SP3) operating system, one free USB port.
Power Requirements: User replaceable, 3.6V lithium battery.
Battery Life: 1 year (approx).
Interface: USB port (interface cable required).
Material: Stainless steel.
Weight: 12 oz (340 g).
Agency Approvals: CE.

Windows

®

and Windows NT

®

are registered trademarks of Microsoft.

6-15/64 [158.43]

ø1-1/4

[31.75]

1/4 NPT CONNECTION

ш1[25.40]

Advertising