1 i/o customer units, I/o customer units, Table 34: customer unit basic i/o, sk cu1-bsc – NORD Drivesystems MI0700 User Manual

Page 54: Information, Analogue input (differential input)

Advertising
background image

Frequency inverters

– Migration Guide SK 700E to SK 5xxE

54

MI 0700 GB-0414

3.2.1 I/O customer units

To connect I/O control signals to the SK 700E frequency inverters, 6 different I/O customer units are
offered. In contrast, the SK 5xxE series of frequency inverters by default comes with respective
onboard terminals to connect the I/O control signals. Please heed the differing terminal
numbers/terminal names (e.g. terminal 42 / VO 15V, terminal 44 / VI 24V or VO 24V) for the different
power supplies of inputs and outputs of the SK 5xxE frequency inverter types or sizes.

SK 700E

Name

Function

[factory setting]

SK 5xxE

Customer unit

SK CU1-BSC

Part No.

Connector

Terminal No.

Name

Terminal strip

Terminal No.

Name

SK 5xxE
onboard

Part No.

Basic I/O

SK CU1-BSC

X3.1

01

REL1.1

Relay 1 / output 1

NO relay contact

[brake control

{1}

]

X3

1

K1.1

X3

02

REL1.2

2

K1.2

X3.2

11

VREF 10V

10 V reference voltage

X4

11

VO 10V

12

AGND/0V

0 V analogue

12

GND/0V

X4

13

AIN1 -

analogue input 1 -

12

GND/0V

14

AIN1 +

analogue input 1 +

[setpoint frequency {1}]

14

AIN1

278200000

X3.3

21

DIG IN 1

digital input 1

[release right {1}]

X5

21

DIN1

X5

275xxxxxx

22

DIG IN 2

digital input 2

[release left {2}]

22

DIN2

23

DIG IN 3

digital input 3

[Par. record switchover
{8}]

23

DIN3

42

VO + 15V

15 V supply voltage

42*
44*

VO 15V
VI 24V
VO 24V

*

Depending on the frequency inverter types and sizes, the supply voltages, terminal numbers or terminal names differ.
Terminal X5: 42 / VO 15V for SK 500E, SK 510E, SK 511E, SK 520E, SK 530E and SK 540E, all sizes 1 - 4
Terminal X5: 44 / VI 24V for SK 505E, SK 515E, SK 535E and SK 545E, all sizes 1 - 4, VI 24V is mandatory for 24 V supply
of the digital inputs and the control unit of the frequency inverter. This terminal is also available on terminal block X7, X12
and X15.
Terminal X5: 44 / VO 24V for SK 505E, SK 515E, SK 535E and SK

545E, ≥ size 5, VO 24V is available as 24 V output

voltage for supplying the digital inputs. This terminal is also available on terminal block X7.

For more information, refer to manuals BU 0500 or BU 0505 (see

www.nord.com

).

Table 34: Customer unit Basic I/O, SK CU1-BSC

Information

Analogue input (differential input)

When using the analogue input of the Basic I/O SK CU1-BSC customer unit , implemented as differential input, it
must be taken into consideration that the SK 5xxE frequency inverters only feature non-isolated analogue inputs!
This also applies to the basic I/O of type SK CU1-STD for SK 700E frequency inverters.

Advertising