3 power and control terminal connection – NORD Drivesystems MI0700 User Manual

Page 61

Advertising
background image

3 Power and control terminal connection

MI 0700 GB-0414

61

SK 700E

Name

Function

[factory setting]

SK 5xxE

Customer unit

SK CU1-PBR

Part No.

Connector

Terminal No.

Name

Terminal strip

Terminal No.

Name

SK 5xxE
onboard

Part No.

DIP left

PROFIBUS DP RTA

Sliding
switch
SUB-D9

ON = bottom
OFF = top

[Default = OFF]

activatable 120

terminal resistor

DIP
right

PROFIBUS DP RTB

*

Depending on the frequency inverter types and sizes, the supply voltages, terminal numbers or terminal names differ.
Terminal X5: 42 / VO 15V for SK 500E, SK 510E, SK 511E, SK 520E, SK 530E and SK 540E, all sizes 1 - 4
Terminal X5: 44 / VI 24V for SK 505E, SK 515E, SK 535E and SK 545E, all sizes 1 - 4, VI 24V is mandatory for 24 V supply
of the digital inputs and the control unit of the frequency inverter. This terminal is also available on terminal block X7, X12
and X15.
Terminal X5: 44 / VO 24V for SK 505E, SK 515E, SK 535E and SK

545E, ≥ size 5, VO 24V is available as 24 V output

voltage for supplying the digital inputs. This terminal is also available on terminal block X7.
For more information, refer to manuals BU 0500 or BU 0505 (see

www.nord.com

).

**

For more information on the technology unit SK TU3-PBR, refer to manual BU 0020 (see

www.nord.com

).

As an option, the technology unit SK TU3-PBR-24V (27590160) can be operated with an external 24 V power supply. Manual
BU 0020 provides more information.

Table 38: Field bus customer unit PROFIBUS DP, SK CU1-PBR

Advertising