Configuration, Led displays – NORD Drivesystems TI 275281167 User Manual

Page 4

Advertising
background image

EtherCAT Bus module – SK TU4-ECT-C

4

TI 275281167 - 4913

Schematic diagram - electrical connection

(Terminal designation on example of NORD frequency inverter SK 180E … SK 2xxE)

SK TI4-TU4 BUS

SK 180E … SK 2xxE

VI 24V

GND/0V

SYS +

SYS -

24V

GND/0V

SYS +
SYS -

Pos : 16 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Et herC at/ Konfig urati on [ SK TU4- ECT(-C)] @ 3\ mod_1371803549598_388. doc x @ 79327 @ 5 @ 1

Configuration

In general, no settings need to be made on the device. However, via the "Hot Connection Group"
functionality, the module can be configured with a fixed address, the so-called "Second Address". This
is carried out via the DIP switches of the module. The DIP switch settings are read after a "Power On"
of the module.

.

DIP switch

Meaning

12

11

10

9

8

7

6

5

4

3

2

1

Address

0

0

0

0

0

0

0

0

0

0

0

X

0

0

0

0

0

0

0

0

0

0

0

1

X

1

0

0

0

0

0

0

0

0

0

1

0

X

2

-

-

-

-

-

-

-

-

-

-

-

X

-

1

1

1

1

1

1

1

1

1

1

1

X

2047

0

System bus
terminating resistor
not set

1

System bus
terminating resistor
set

Pos : 19 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Et herC at/ LED Anz eigen [ SK TU4- ECT(-C)] @ 3\mod_1371804043826_388.doc x @ 79352 @ 5 @ 1

LED displays

The operating statuses of the module are visualised using LED indicators.

No.

Name

Colour

Meaning

1

RUN

green

Ethernet State

ERR

red

Ethernet Error

DS

green

Device status

DE

red

Device error

2

Link/Act

green

Link/Activity

Pos : 20 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ Et herC at/ LED Anz eigen- EtherCAT spezifis che LED [ ECT Allgemei n] @ 3\ mod_1371732026091_388. doc x @ 79187 @ @ 1

1

12

ON

OF

F

Advertising