Configuration

Configuration of the module for remote maintenance is carried out via the DIP switches. The
DIP - switch settings are read after a "Power On" of the module.

DIP switch

Meaning

12

11

10

9

8

7

6

5

4

3

2

1

X

X

X

No function

Access rights for remote maintenance

0

Only read access to parameters possible.

1

Read and write access to parameters possible.

0

No control possible.

1

Control is possible.

0

TCP/IP open connection.

1

Secure TCP/IP connection.

1. (DIP 1 - 9)

No function

2. Access rights for remote maintenance (DIP 10 – 12)

Via the Ethernet protocols TCP and UDP the module
and the connected frequency inverter can be
accessed using remote maintenance. The type of
access is determined via the DIP - switch with inputs
10 to 12.

Pos : 20 /T echnisc he I nf ormati onen/ SK xU x - Bus - Erweit erungen/ PROF INET IO /LED Anzeigen [SK TU 3-PNT ] @ 4\ mod_1385046540406_388.doc x @ 106099 @ 5 @ 1

LED indicators

The operating statuses of the module are visualised using LED indicators.

No.

Name

Colour

Meaning

1

RUN

green

Ethernet State

BF

red

Ethernet Error

DS

green

Device status

DE

red

Device error

2

Link

green

Link

Activity

yellow

Activity