10 Technical data

10.1 Specifications

General

HF52

HF53 / HF54 / HF56

HF556 / HF557 / HF566

Device type

Humidity temperature
transmitter with analog
output signals

Humidity temperature
transmitter with analog
output signals and
optional digital output

Humidity temperature
transmitter with digital
output

Circuit type

2-wire, loop powered

3-wire

Mechanical configuration types

D and W

Power supply and connections

HF52

HF53 / HF54 / HF56

HF556 / HF557 / HF566

Supply voltage (VDD)

10…28VDC
V min = 10 V + (0.02 x
Load*) *Load
resistance in ohms.

HF53: 15…40 VDC or
12…28 VAC

HF54: 9 to 36 VDC or
7 to 24 VAC
Galvanic isolation

HF56: 85 to 240 VAC
47 to 63 Hz
Galvanic isolation

HF556

: 5…40 VDC or

12…28 VAC

HF557: PoE

HF566: 85 to 240 VAC
47 to 63 Hz

Typical current consumption

2 x 20 mA

HF53 / HF54: 100 mA

HF56:
< 50 mA at 85 VAC
< 35 mA at 240 VAC

HF 556: with USB
interface: 100 mA

HF556 / HF557 with
Ethernet interface: 300
mA

HF566:
< 50 mA at 85 VAC
< 35 mA at 240 VAC

Electrical connections

Terminal blocks and 1 x
M16 cable

grip or ½”

conduit adapter

HF53 / HF54:Terminal
blocks and 1 x M16
cable grip or ½” conduit
adapter

HF56: Terminal blocks
and 2 x M16 cable grip
or ½” conduit adapter

HF556: Connector (USB
or Ethernet), terminal
blocks (power supply
and RS-485) and 1 x
M16 cable grip or ½”
conduit adapter

HF557: Ethernet
Connector

HF566: Connector (USB
or Ethernet), terminal
blocks (power supply
and RS-485) and 2 x
M16 cable grip or ½”
conduit adapter

Polarity protection

Protective diode on V+ (except HF56, HF57 and HF58)

Fuse

HF56 / HF566: 2A fuse, soldered to PCB


Humidity and temperature
measurement

See document E-M-HC2 Probes > Specifications