Chapter 4: controls – Sterlco SDA Series Medium Capacity Dehumidifying Dryer User Manual

Page 16

Advertising
background image

Cabinet Series Dehumidifying Dryer

16

Chapter 4: Controls

4-1 Control Panel Indicator Lights and Switches

Rocker Switches

System ON/OFF Rocker Switch

Used to de-energize control power to the indicator panel, allowing separate control of the dryer
and conveying systems.

Dryer ON/Sequence Shutdown Rocker Switch

Used to start the dryer. Move this switch to the Sequence Shutdown position to turn off the
process heaters, finish the regeneration cycle and then turn off the dryer.

Optional Alarm Silence Rocker Switch

Press the Alarm Silence switch to silence the horn when a high temperature alarm activates.
The alarm repeats every five minutes until the problem causing the alarm condition is cleared.

Indicating Lights

Indicator

Name

Description

G

Regen Blower
On Light

The Regen Blower On indicator lights when the
regeneration blower energizes.

G

Left Bed In
Regen Light

The Left Bed In Regen LED lights when the left bed
is in regeneration.

G

Left Bed Heater
Light

The Left Bed Heater indicator lights when the left
bed regenerates and is in the heat-up portion of the
regeneration cycle.

G

Right Bed In
Regen Light

The Right Bed In Regen LED lights when the right
bed is in regeneration.

G

Right Bed Heater
Light

The Right Bed Heater indicator lights when the right
bed regenerates and is in the heat-up portion of the
regeneration cycle.

G

Process Blower
On Light

The Process Blower On indicator lights when the
process blower energizes.

G

Process Heater
On Light

The Process Heater On indicator lights when the
process air heater is energized.

R

Low Compressed
Air Light

The Low Compressed Air alarm indicator lights
when the dryer compressed air supply drops below
60 psi (413kPa/ 4.13 bars). Upon loss of

Advertising