Cabinet Series Dehumidifying Dryer

46

Option Type

RE232C

RS-485

Event Input

Transfer Output

Board Number

E53-CK01

E53-CK03

E53-CKB

E53-CKF

Mode Parameter

Setting

range

Default

Factory

setting

Option Eu-A Multi-SP Function

0/1

0

Default

Option Eu-1 Event Input Assign 1

STOP/MAN

STOP

Default

Option SbCE Communication Stop Bit

½ BITS

2

Default

Option Len Comm. Data Length

7/8 BITS

7

Default

Option PrEY Commication Parity

None/Even/Odd

Even

Default

Option 6PS Comm. Baud Rate

1.2/2.4/4.8/9.6/19.2

9.6 kbps

Default

Option U-n6 Comm. Unit No.

0 to 99

0

Default

Option Er-E Transfer Output Type

SP/SP-M/PV/O/C-O

SP

Default

Option Er-H Xfer Output Upper Limit

5

5

Default

Option Er-L Xfer Output Lower Limit

5

5

Default

Restoring Factory Defaults on the Dew Point Controller

1. Make sure jumper setting for input type is set for Current Input (I), right jumper.

2. Return controller to housing.

3. Press the Display button for one (1) second to enter Menu Display.

4. Press the Arrow Up button to switch between menus.

5. To switch parameters within a menu, press Up Arrow button.

Figure 9

Setting List for Dew Point Controller, Part No. A0548567

Mode Parameter

Setting

range

Default

Factory

setting

Protect SECr Security

0 to 6

1

3

Protect YEYP A/M Key Protect

ON/OFF

OFF

ON

Manual Manual MV

-5.0 to 105.0 %

0.0

Default

Level 0 SP Set Point

SP lower limit to upper limit EU

0

Default

Level 0 r-S Run/Stop

Run/Stop

Run

Default

Level 1 AL-1 Alarm Value 1

-1999 to 9999 EU

0

-10.0

°F/-23°C

Level 1 AL-2 Alarm Value 2

-1999 to 9999 EU

0

-10.0

°F/-23°C

Level 1 C-db Dead Band

-19.99 to 99.99%FS

0.00

Default

Level 1 HYS Hysteresis (Heat)

0.01 to 99.99% FS

0.10

Default

Level 1 CHYS Hysteresis (Cool)

0.01 to 99.99 FS

0.10

Default

Level 2 SPrU Sp Ramp Time Unit

M(Minutes)/H(Hours)

M

Default

Level 2 SPrt Sp Ramp Set Value

0 to 9999 EU

0

Default

Level 2 CnF Input Digital Filter

0 to 9999 SEC

0

Default

Level 2 ALH1 Alarm 1 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 ALH2 Alarm 2 Hysteresis

0.01 to 99.99%

0.02

Default

Level 2 Cn5H input shift upper limit

-199.9 to 999.9

°C

0.0 Default