4-6 Setting the Process Air Temperature

To change the process air temperature set point with the dryer running:

„ Press the Up Arrow button to increase the set point to the temperature you want.

„ Press the Down Arrow button to lower the set point to the temperature you want.

„ Press the Auto-tune button to initiate auto-tuning.

4-7 PLC

Controller

The PLC controller uses an Allen-Bradley programmable logic controller (PLC). This “brick”-
type controller has 32 I/O points: twenty (20) inputs and twelve (12) outputs, all inputs and
outputs are 115 VAC.

All programming and logic is factory-installed on an EEPROM chip and cannot be modified. A
battery backup retains programming if power fails. Battery life is five (5) years at room
temperature.

If the alarm indicator blinks intermittently, replace the battery within one week.